Riyadh, Saudi Arabiaالعربية
Home / Services / Inert gas fire suppression IG-541 and IG-55
Authorized distributor · ROTAREX · INEREX

Inert gas fire suppression in Riyadh

We design, install and maintain inert gas fire suppression systems with IG-541 and IG-55 agents and the ROTAREX INEREX system, protecting server rooms, data centers, archives and museums across Saudi Arabia as an authorized distributor in the Kingdom.

ROTAREX INEREX inert gas fire suppression system
Inert gas

IG-541 and IG-55 with ROTAREX components

Natural gases found in the air. They put out the fire by lowering the oxygen level in the room and leave no residue on equipment.

IG-541N₂ · Ar · CO₂

IG-541 agent

A blend of nitrogen (52%), argon (40%) and carbon dioxide (8%).

  • Zero ozone depletion and zero global warming potential
  • Safe for occupied spaces when designed to NFPA 2001
  • No residue and no harm to equipment
IG-55N₂ · Ar

IG-55 agent

A blend of argon (50%) and nitrogen (50%).

  • Natural agent with no chemicals
  • Suits large areas and multiple rooms
  • No residue and no harm to equipment
INEREX by ROTAREX

Why INEREX?

UL, FM and VdS approved

A complete, tested and certified system, ready to design and install.

ROTAREX constant-flow pressure regulator

Constant-flow pressure regulator

Reduces pipework pressure to 40–60 bar, so easier and lower-cost Schedule 40 pipework can be used and pressure relief vents get smaller.

INEREX silent nozzle

Silent nozzles for data centers

Keep discharge noise below 110 dB, ideal for server rooms and data centers.

Discharge within 60 seconds

Reaches design concentration within 60 seconds and prevents discharge freezing and pressure peaks.

Single or multi-zone

One system protects a single room or several zones.

Easier maintenance

After discharge, remove the regulator, recharge and reconnect with no reconditioning. Functional tests are possible while the system stays armed.

Our services

From design to approval

Design and calculations

Agent quantity, cylinder count and nozzle layout based on room volume, NFPA 2001 and ISO 14520.

Supply

Genuine INEREX system and ROTAREX components for 200 and 300 bar systems, with authorized-distributor warranty.

Installation and commissioning

Cylinders, piping, nozzles and pressure relief vents, connected to the releasing panel.

Room integrity test

We confirm the room holds the agent for the required time, with Retrotec certified technicians. Test details →

Fire alarm interface

Connection to the fire alarm and releasing panels from Hochiki and Potter.

Maintenance and refilling

Periodic maintenance, cylinder pressure checks and refilling after discharge.

Applications

We protect

Server rooms and data centers
Electrical and transformer rooms
Telecom rooms
Archives and records
Museums and libraries
Banks
Hospitals and laboratories

Why inert gas?

A natural agent with zero environmental impact that does not break down in fire or leave residue, and suits large areas and multiple rooms from one cylinder bank. DSL is an authorized ROTAREX distributor in Saudi Arabia and licensed by HCIS.

FAQ

Common questions about inert gas

What is an inert gas fire suppression system?

It releases natural gases such as nitrogen and argon into the room, lowering the oxygen to a level that puts out the fire while remaining suitable for people during evacuation when properly designed.

What is the difference between IG-541 and IG-55?

IG-541 is a blend of nitrogen, argon and carbon dioxide; IG-55 is an equal blend of argon and nitrogen. Both work the same way, and we choose based on the project requirements.

IG-541 vs FM-200: which one should I choose?

FM-200 needs fewer cylinders and less storage space. Inert gas is a natural agent with zero environmental impact and suits large areas and multiple rooms, but it needs more cylinders and pressure relief vents. We help you choose based on the room. FM-200 and Novec systems →

Is inert gas safe for people?

Yes, when designed to NFPA 2001, with a pre-discharge alarm so occupants can leave.

What does ROTAREX do in the system?

ROTAREX makes the cylinder valves and pressure regulators that control the flow of gas from 200 and 300 bar cylinders into the pipe network, the core of the system.

Does the system need a room integrity test?

Yes. The test confirms the room holds the agent for the required hold time, carried out by Retrotec certified technicians. Room integrity test →

Is the INEREX system approved?

Yes. The ROTAREX INEREX system is UL, FM and VdS approved, and compatible with all inert gas agents at 200 or 300 bar.

Why use silent nozzles in data centers?

Silent nozzles keep inert gas discharge noise below 110 dB, which matters in server rooms and data centers.

Do you work outside Riyadh?

Yes, we deliver inert gas systems across Saudi Arabia, including Riyadh, Jeddah and Dammam.

Need a quotation for an inert gas system?

Send us the room dimensions and use, and we will come back with a proposal.

Request a quotation on WhatsApp amahmoud@dsl-ksa.cominfo@dsl-ksa.com
Need help with a project?Chat with our team on WhatsApp