Room Integrity Test in Riyadh, Saudi Arabia
We carry out room integrity tests for spaces protected by gas fire suppression systems in Riyadh and across Saudi Arabia, using Retrotec door fan equipment and Retrotec-certified technicians, to NFPA 2001 and ISO 14520, to confirm the room will hold the extinguishing agent long enough to put the fire out.

Room integrity testing, from survey to report
Discharging the agent is not enough. The room has to hold it, or it leaks out before the fire is out. That is what this test measures.
Retrotec door fan test
We fit Retrotec door fan equipment to the room door, pressurize and depressurize the room, and measure leakage precisely.
Hold time calculation
We calculate how long the room holds the agent concentration and compare it with the required minimum, typically 10 minutes.
Leak location
We locate leaks in walls, ceilings, floors, doors, cable penetrations and HVAC openings.
Sealing advice & retest
Clear recommendations to seal the leaks, and a retest after sealing until the room passes.
Test report
A detailed technical report with results and calculations, for project handover and annual compliance.
Annual retest
We retest annually or after any change to the room so the system stays effective.
How we carry out the test
- Survey & dataRoom volume, agent type and design concentration, and the highest protected equipment.
- Room preparationDoors and openings closed and HVAC and extraction shut down, as at discharge.
- Door fan setupThe fan is fitted to the door and connected to the gauges.
- Pressurize & depressurizeWe measure pressure difference and air leakage over several readings.
- Calculation & resultWe calculate leakage area and hold time and confirm pass or fail.
- Report & follow-upYou receive the report and recommendations, with a retest after sealing if needed.
Rooms that need an integrity test
Why DSL
We install Tyco HYGOOD FM-200 and SAPPHIRE FK-5-1-12 gas suppression and understand the calculations behind the test. We use genuine Retrotec equipment, our technicians are Retrotec certified with accredited training, and we are licensed by HCIS, and test rooms even when another contractor installed the system.
Room integrity test questions
What is a room integrity test?
A test that measures whether a room protected by a gas suppression system can hold the agent for the required time. It is done with a door fan, without discharging the agent.
Are your technicians Retrotec certified?
Yes. DSL is certified by Retrotec, our technicians hold accredited Retrotec training certificates, and we use genuine Retrotec door fan equipment.
Why is the integrity test important?
If the room leaks, the agent escapes before the fire is out and the system cannot do its job. The test confirms your suppression system will work when it is needed.
Which standards do you follow?
NFPA 2001 (Annex C) and ISO 14520, the recognized standards for clean agent fire suppression systems.
What hold time is required?
Typically a minimum of 10 minutes, unless the authority having jurisdiction requires longer.
Does the test discharge the agent?
No. The door fan test measures leakage with air only, without discharging the agent or a long shutdown of the room.
How long does the test take?
Usually one to two hours per room, depending on size and preparation.
How often should the room be retested?
We recommend annually, and after any change to the room such as new cable penetrations or changes to the ceiling, doors or HVAC.
Do you test systems installed by others?
Yes. We test any room protected by FM-200, FK-5-1-12 or inert gas, whoever installed the system.
Do you work outside Riyadh?
Yes. We carry out room integrity tests across Saudi Arabia, including Riyadh, Jeddah and Dammam.
Need an integrity test for your room?
Send us the room size and suppression system type and we will come back with a date and price.