Riyadh, Saudi Arabiaالعربية
Home / Services / Potter fire alarm systems
Authorized distributor · Potter

Potter fire alarm systems in Riyadh, Saudi Arabia

We supply, install and maintain Potter systems across Saudi Arabia: AFC Series and IPA-60 addressable fire alarm panels, the CRC-300 releasing control panel, and Integrated Voice and EVAX voice evacuation systems, as an authorized distributor in the Kingdom.

Potter fire alarm panels and devices
Potter products

Potter fire alarm and voice evacuation solutions

Addressable panels with their detectors and modules, releasing panels and voice evacuation, selected for your building and handed over fully commissioned.

AFC SeriesAddressable

Potter AFC Series addressable fire alarm panels

Potter AFC addressable panels give every device its own address, so the exact alarm point shows on the panel.

  • AFC-50: 50-address addressable panel
  • AFC-100: addressable panel for mid-size buildings
  • AFC-1000E: up to 1,270 addresses, expandable
  • PAD300 addressable smoke and heat detectors
  • PAD300 input/output modules and PAD100 pull stations
  • PSN-1000 intelligent power supplies
IPA-60IPA Series

Potter IPA-60 addressable fire alarm panel

The Potter IPA-60 is a 60-address addressable panel listed for releasing, suited to small buildings and equipment rooms.

  • 60 addresses for detectors and modules
  • Two programmable NACs
  • 5 A expandable power supply
  • Gas suppression releasing control
  • UL and FM listed
CRC-300Releasing control

Potter CRC-300 releasing control panel

The Potter CRC-300 is a conventional single-hazard releasing control panel that detects fire and releases the suppression system automatically.

  • For gas suppression, pre-action and deluge systems
  • Two detection zones and five initiating circuits
  • Built-in programs and cross zoning
  • UL, FM and CE
Integrated VoiceIntegrated voice

Potter Integrated Voice evacuation

Addressable fire panels with built-in voice evacuation that broadcast recorded or live evacuation messages with the alarm.

  • AFC-1000V and IPA-4000V panels
  • SCA-2525, SCA-2570 and SCA-5025 amplifiers
  • RM-1000ECS remote microphone and LOC-1000 local operator console
EVAX SeriesConventional voice

Potter EVAX voice evacuation systems

Standalone voice evacuation panels that work with any fire alarm system and guide people to the exits with clear voice messages.

  • EVAX-5070, EVAX-10070 and EVAX-X70 panels
  • CIM-16 contact input module for the fire panel interface
  • Recorded evacuation messages and live paging
What we do

From design to handover

Design

Potter system design with detector and speaker layout based on your drawings and the applicable code.

Supply

Genuine Potter equipment with authorized-distributor warranty.

Installation & programming

Installation, cabling, Potter panel programming and full commissioning.

Integration

Interfaces with voice evacuation, gas suppression, lifts and HVAC.

Testing & handover

Full testing and handover with as-built drawings and training.

Maintenance

Preventive maintenance contracts for Potter systems and technical support.

Sectors

Who we serve

Government
Hospitals
Universities & schools
Factories & warehouses
Malls & hotels
Offices & towers
Data centers
Residential compounds

Why DSL

Authorized Potter distributor in Saudi Arabia and licensed by HCIS. We design, install and maintain fire alarm, voice evacuation and suppression systems under one roof.

FAQ

Potter questions

Is DSL an authorized Potter distributor in Saudi Arabia?

Yes. Digital Standards Ltd is an authorized Potter distributor in the Kingdom and supplies genuine equipment with distributor warranty.

What is the difference between the AFC panels and the IPA-60?

AFC panels start at 50 addresses and reach 1,270 addresses with the AFC-1000E, for small to large buildings. The IPA-60 is a 60-address panel listed for releasing. We help you choose based on the building.

What is the CRC-300 used for?

The Potter CRC-300 controls the release of a suppression system for a single hazard, such as server or electrical rooms, and works with gas suppression, pre-action and deluge systems.

What is the difference between Integrated Voice and EVAX?

Integrated Voice is built into the addressable fire panel, while EVAX is a standalone voice evacuation panel that can connect to any fire alarm system.

Do you interface Potter fire alarm with gas suppression?

Yes. The CRC-300 and Potter addressable panels control the release of FM-200 and FK-5-1-12 systems, as well as pre-action and deluge sprinklers.

Do you offer maintenance contracts?

Yes. We offer preventive maintenance contracts for Potter systems and technical support after handover.

Where can I buy Potter fire alarm panels in Saudi Arabia?

From DSL, an authorized Potter distributor in the Kingdom. We supply the Potter IPA-60, AFC Series and CRC-300 panels with their detectors and voice evacuation systems, from Potter Electric Signal Company in the USA.

Do you work outside Riyadh?

Yes. We deliver Potter projects across Saudi Arabia, including Riyadh, Jeddah and Dammam.

Need a quotation for a Potter system?

Send us your drawings or building details and we will come back with a proposal.

Request a quotation on WhatsApp amahmoud@dsl-ksa.cominfo@dsl-ksa.com
Need help with a project?Chat with our team on WhatsApp